Date: 4/5/2010 Author: J. Zhang (jzhang@sandia.gov) This file is to decribe the flame. Ethylene Piloted Jet Diffusion Flame Re = 20,000 = U_J*d_i/nv 1. Geometry of burner (1) Inner fuel tube: d_i = 3.2 mm, d_o = 4.6 mm (2) Outer tube: D_i = 15.2 mm, D_o = 19.1 mm (3) Length of fuel tube: ~ 527 mm. 2. Main fuel jet (1) C2H4 (pure); (2) U_J = 54.7 m/s; (3) flow rate 26.4 slpm (volumetric) 3. Pilot mixture (1) C2H4 and air mixture, Phi = 0.90 (2) 2% heat release rate of the main fuel jet (3) flow rate 8.91 slpm (volumetric), or 10.63 g/min (mass) 4. Coflow Air: 21 to 22 deg C, 0.61 to 0.66 m/s, 45% relative humidity. 5. Visible flame height = 830 mm. 6. Room temperature: ~ 22 deg C. Standard conditions for flows defined to be 298 K and 1 atm pressure.